Synchronised 660-1100KVA

Synchronised or Parallel Generator Systems for Sale (2 or more Generators working in parallel)

Able's Synchronised power range is in stock ready to go anytime. All our Generators 176 kVA and above are Synchronise Ready.

 Advantages of Synchronised Generators are :

  • Built in Redundancy in the unlikley event of generator failure - The other Generators keep the site powered.
  • Convenient Servicing while the other Generators keep your site running giving no downtime.
  • Flexible System for varying power requirements - Increase or Reduce your number of Generators easily.
  • Underloading of Generators is Limited due to Flexible Generator Useage Options.
  • Lower Initial Investment Cost Savings - Sometimes Can be Cheaper than Purchasing 1 Large Generator.
  • Fuel Useage is Similar or Better to Single Generator Systems.
  • Can be Setup for 90% Plug & Play Operation.
  • Any Combination of Generators can be Used in Parallel.
  • All Generators can be Monitored and Controlled Offsite via the Internet.

 

Call the Generator Synchronisation Experts today at Able Sales

SYNCH350+250
  • STANDARD ABLE PRODUCT LINE !!!
  • Cummins Powered
  • Cummins Reliability
  • Cummins Australia Warranty
  • Stamford Alternators
  • 660 kVA 415 Volt
  • Water Cooled
  • Silenced 72 dB at 7 metres
  • MineSpec Bunded
  • Australian Compliant
  • Full RCD & M.E.N. Wiring
  • Easy connect ATS plug
  • Remote Start Systems Available
$106,800
inc. GST
More Information

SYNCH350+350
  • STANDARD ABLE PRODUCT LINE !!!
  • Cummins Powered
  • Cummins Reliability
  • Cummins Australia Warranty
  • Stamford Alternators
  • 770 kVA 415 Volt
  • Water Cooled
  • Silenced 75 dB at 7 metres
  • MineSpec Bunded
  • Australian Compliant
  • Full RCD & M.E.N. Wiring
  • Easy connect ATS plug
  • Remote Start Systems Available
$119,800
inc. GST
More Information

SYNCH500+350
  • STANDARD ABLE PRODUCT LINE !!!
  • Cummins Powered
  • Cummins Reliability
  • Cummins Australia Warranty
  • Stamford Alternators
  • 935 kVA 415 Volt
  • Water Cooled
  • Silenced 75 dB at 7 metres
  • MineSpec Bunded
  • Australian Compliant
  • Full RCD & M.E.N. Wiring
  • Easy connect ATS plug
  • Remote Start Systems Available
$148,900
inc. GST
More Information

SYNCH500+500
  • STANDARD ABLE PRODUCT LINE !!!
  • Cummins Powered
  • Cummins Reliability
  • Cummins Australia Warranty
  • Stamford Alternators
  • 1100 kVA 415 Volt
  • Water Cooled
  • Silenced 75 dB at 7 metres
  • MineSpec Bunded
  • Australian Compliant
  • Full RCD & M.E.N. Wiring
  • Easy connect ATS plug
  • Remote Start Systems Available
$178,000
inc. GST
More Information

Parallel Load Sharing Generators

Using multiple or parallel Able gensets load sharing as a Power Management System has many benefits, like saving on fuel costs, equipment replacement can be done easily with a power disruption and improved flexibility with maintenance.

Running generators in parallel or not to parallel diesel generators?

The benefits of parallel generators

Synchronised generators have always been significantly better over a single large generator. Up to now using generator load sharing systems have been limited to large projects like mining or mission-critical uses like hospitals because of the higher cost, space, and level of complexity to set up and maintain.
Able Sales with their use of sophisticated integrated digital control technologies, it has now become cheaper and easier to operate paralleling generators and benefit from them. So, what are the benefits of running generators in parallel or generator paralleling and load sharing?

Replacing Generators in parallel

Greater reliability is offered than by a single generator, if one unit fails, the loads are redistributed among other units in the system. With paralleling generators, this means that the units will have the redundancy necessary to maintain power even if one of the units goes out.

Paralleling Generators Expandability

Parallel diesel generators can match you load requirements as you power needs fluctuate, it is often difficult to accurately project increases in load and adequately plan for anticipated additional requirements. If the load on a single generator is to light it will reduce the life of that machine but with Parallel Generators, it will switch off unnecessary machines. On the other hand, if load projections were to small, you will be left without reliable power or may have to resort to expensive upgrades, or purchasing another unit altogether. By using synchronised generators,

It is easier to allow for variations in load without overrunning your budget or piling up expensive gensets that rarely get used.

This type of generator set up is also known as load sharing in parallel generators, load sharing generators, synchronous generators, synchronized generators, synchronizing generators, synchronised generators, generator paralleling.

Why parallel? Why not simply get a bigger generator?

There are many reasons why somebody might not need to simply buy a bigger generator. The foremost common reason is once somebody already owns an electrical converter generator then discovers later they have a bit additional power needed. This is often smart to buy a further generator to accommodate the increased power desires instead of abandoning their current setup. what is more, electrical converter generators can be more fuel economical and considerably quieter than a comparable sized open frame generator? This is often as a result of larger 4000-5,000+ watt (non-inverter generators) run at an identical throttle till manually adjusted. Electrical converter generators (even once running in parallel) typically have an eco mode and technology to vary throttle supported power demand. Thus, they're is a way additional economical setup and far more moveable. Lastly, there are many parallel capable generators accessible for purchase that are roughly constant cost as an equivalently power-driven open frame unit. Having 2 generators offers additional flexibility supported power desires AND a possible backup if one were to fail while off the grid. Of course, one unit alone won't run an AC unit, however at the smallest amount would run the fundamentals.

Parallel generators does it harm the Generators?

Running synchronised generators isn't a harmful exercise as long as they're 2 generators that are designed to be run in this manner. Moreover, most generators need a specific parallel cable to create this work. The explanation for this can be that every generator has its own laptop within. They're not designed to figure well together among totally different makers. This synchronization is usually solely attainable if the makers are identical like most powerful Able generators are.

Testimonials Testimonials

GeoTrust Seal - Click to Verify